Workshop
DC motors
  • Cleaning, re-insulation, armature drying, turning and milling of the manifold.
  • Control of the armature winding at the surge-test. Bearing replacement.
  • Cleaning and re-insulation of the rear cover.
  • Check the brushes for wear, adjust them and replace them if necessary.
  • Brush holder height adjustment and linear neutral setting.
  • Electrical overhaul and tacho dynamo control.
  • Brake setting, torque control.
  • Encoder control.
  • Shaft dimensional control.
  • If ventilated: checking, disassembly, cleaning, re-insulation, drying, bearing replacement, assembly and testing.
  • Assembly, testing, data collection and final inspection.

Brushless Motors
  • Stator cleaning, re-insulation and drying.
  • Surge-test winding test.
  • Replacement of bearings and gaskets.
  • Brake setting and torque control.
  • Emitter verification and adjustment: RLG, resolver, integrated RLG and encoder, tachometer.
  • Encoder calibration.
  • Rotor keyway check.
  • Power and emitter connection control.
  • Shaft dimensional control.
  • If ventilated: checking, disassembly, cleaning, re-insulation, drying, bearing replacement, assembly and testing.
  • Assembly of the motor, tests on load bench and tests with its regulator and numerical control.
  • Data collection and final inspection.